SENSE G
Description:
SENSE G is made with a unique extruded aluminium profile. The reduced size of the LED sources allows the product to have a body with reduced dimensions, resulting elegant and thin. Medical gases outlets can be installed in the frontal part of the bedhead unit, giving maximum flexibility to the spaces configuration during the planning phase. Moreover, their position facilitates the doctors and medical staff activities.
General information
- Diffuser: Opal polycarbonate diffuser for reading/examination lighting - Methacrylate diffuser for general lighting
- Protection degree IP: IP20 general - IP40 lighting circuit - IP21 electrical sockets
- Standard colour: Opaque RAL9010
- SURFACE TREATMENT ON REQUEST: Anodization, antimicrobial coating, decorative finishing. Check the possible finishings
- Electrical equipment: White UNEL 2x10 / 16A + T current socket, 3-module decorative plate, 3-button keypad and data socket.
- MEDICAL GAS SYSTEM: 3 preparation (holes) for connection of the terminal units for the passage of medical gases (type according to the customer's technical specification)
Details relating to one bed behead unit 1500 mm long
- General light: 48W - 5672lm - 4000K
- Reading light: 12W - 1056lm - 4000K
- Examination light: 24W - 2112lm - 4000K
- Night light: 3W - 220lm - 4000K
For specific needs, please contact our Sales Department.
CLASSIFICATION ACCORDING TO THE 93/42/CEE DIRECTIVE
- I class (no gas) - IIa/IIb (with gas)
- Non-stop operation
- No sections are applie
- Suitable for the installation in group 0, 1 and 2 medical premises
- Not suitable for the installation in explosion risk environments (locations with gases and flammable vapours)
- Not suitable for the installation in environments with an oxygen amount superior to the 25% with an environmental pressure until the 110kPa in usual circumstances
- Not suitable for the categories AP and APG provisions
REFERENCE DIRECTIVES AND REGULATIONS
93/42/CEE; UNI EN ISO 11197; CEI EN 60601-1; CEI EN 60598; CEI EN 55015; CEI EN 61547; UNI CEI EN ISO 14971; UNI CEI EN ISO 13485
- I class (no gas) - IIa/IIb (with gas)
- Non-stop operation
- No sections are applie
- Suitable for the installation in group 0, 1 and 2 medical premises
- Not suitable for the installation in explosion risk environments (locations with gases and flammable vapours)
- Not suitable for the installation in environments with an oxygen amount superior to the 25% with an environmental pressure until the 110kPa in usual circumstances
- Not suitable for the categories AP and APG provisions
REFERENCE DIRECTIVES AND REGULATIONS
93/42/CEE; UNI EN ISO 11197; CEI EN 60601-1; CEI EN 60598; CEI EN 55015; CEI EN 61547; UNI CEI EN ISO 14971; UNI CEI EN ISO 13485
TELL YOUR NEEDS
We are specialists in designing customized lighting solutions in a short time.
If you are an architect, a designer or a manager, contact us to explain your needs in detail.
We are specialists in designing customized lighting solutions in a short time.
If you are an architect, a designer or a manager, contact us to explain your needs in detail.